公司介绍核心竞争力纳米技术半导体芯片基因编辑技术人工智能恒温水浴锅&低温冷阱循环浴槽-低温恒温器冷水机-冷却水循环器烘箱-真空干燥箱马弗炉-高温电炉恒温生化培养箱恒温摇床-振荡培养箱振荡器-混匀仪加热磁力搅拌器-电热板顶置式搅拌器-行星式搅拌机-三辊研磨机防潮箱-真空干燥器真空泵超声波清洗机灭菌锅实验室常用设备恒温恒湿箱-高低温交变(湿热)试验机综合药品稳定性试验箱高低温交变试验箱冷热冲击试验箱-温度冲击试验机快速温湿度变化试验箱盐雾腐蚀试验箱环境试验箱恒温金属浴-干浴器电泳仪-电源差分细胞计数器生命科学设备防火安全柜废液收集系统耐酸耐腐蚀储藏柜净气型试剂柜安全储藏柜超净工作台无管道通风柜迷你通风柜移动臂式万向抽风罩悬臂式集气罩PCR工作台紫外线灭菌柜通风柜-洁净台分光光度计TOC总有机碳分析仪微波消解仪分析仪器王研式透气度测试仪图像法粒度粒形分析仪物性测试设备手部防护用品面部防护用品身体防护用品安全防护用品行业新闻公司新闻产品知识常见问题Newsletter实验室搅拌方案实验室振荡方案实验室加热方案实验室制冷方案按用途分类透湿量测试按工艺分类
产品详情
分享到:

防火安全柜_EN 14470-1标准

型号: SC2-60F-0806D1-CL
品牌: Lab Companion
参数: 内部容积:99升,耐火时间:60分钟
用途: 储藏可燃样品、试剂、重要文件资料等
技术参数
性能特点
可选配件
产品评论(0)

基本参数

Specification (Type 60)

Model

SC2-60F-0806D1-CL/SC2-60F-0806D1-CR

SC2-60F-0706D1-C

Internal volume (L)

89

76

Interior dimensions

(W x D x H, mm)

505 x 419 x 422

505 x 419 x 362

Exterior dimensions

(W * D *H, mm)

600 x 610 x 820

600 x 610 x 720

Max. load (kg)

80

80

CE certification

O

O

Weight (kg)

106

100

Cat. No.

AAAF360310
AAAF360311

AAAF360110

Product appearance

SC2-60F-0806D1-CL

SC2-60F-0706D1-C

Product interior

SC2-60F-0806D1-CR

60F_spec_img04_inner.jpg

1) Drawer Type is the maximum load for theDrawer.

Diverse certifications obtained

  • Only one in Korea to obtain CE (EN14470-l) certification.

  • Acquired Certificate of Excellent Product from the Public Procurement Service in Korea.

  • Acquired performance certification from the Ministry of SMEs and Startup in Korea.

  • Awarded the 2018 Safe Korean Technology Prize by the Ministry of the Interior and Safety.

  • * EN14470-1 verifies that the equipment meets the European safety standards for dangerous goods containers such as fire resistance, internal ventilation, shelf stability, and automatic door closure.

Safe storage from fire

  • High fire resistance

  • Fire resistance performance is in accordance with the strictest European standard, with the internal temperature kept below 180K for up to 90 minutes in the event of fire.

  • Fire Response Sealing System

  • When the temperature reaches 50°C, the door automatically closes. When the ambient temperature reaches 70±10°C, the exhaust holes and ventilation openings are automatically closed, totally blocking the flow of heat from the outside in the event of fire

  • The right model for the application can be selected

  • Possible to suppress fire at the natural ignition point of the dangerous goods being handled.

  • Model selected considering the prediction time, etc.

  • Chemical resistant interior material

  • Excellent chemical resistance even for long-term use with the interior material coated with polyphenol resin.

  • Under bench type height-adjustable (SC3 Under-type Model)

  • 750 mm/820 mm height can be selected considering the work height when hood is installed at the bottom.

Solid and secure shelf structure

  • Solid shelf structure

  • It is a solid structure allowing for up to 80kg to be held per shelf and it can be fixed firmly to the left and right inside walls

  • Safe shelf design

  • With 30mm-deep shelf shape for safe storage, it is designed to be safe even if the stored contents are leaked.

  • Right shelf selection

  • The built-in shelf is excellent in chemical resistance due to epoxy powder coating. Also, stainless steel shelves and PP trays can be selected. (optional).

Proven fireproof performance!

Items Proven by Testing

30 minutes / 60 minutes / 90 minutes fire resistance performance test.

For fire test according to standards of EN 1363-1, the time required for AT to be kept below 180°C is expressed as fire resistance (EN-14470-1).

cb_all_minutes_07.jpg

Key lock device

cb_all_minutes_09.jpg

Effluent reservoir

Safe handling in the event of stored material leakage and prevention of leakage out of the cabinets.

Key lock device

Key lock is provided as standard to block unauthorized access.

Safe stored materials handling

Ergonomic structure with easy access to shelves for user's safety and convenience.

cb_all_minutes_10.jpg

cb_all_minutes_11.jpg


Convenient moving and installation

Forklift fork space for convenient movement.

Leveling feet for stable installation.

Extraction Module (option)

Filters flammable gas inside the cabinet with a carbon filter without connecting a separate duct


EN 14470-1

NFPA 30

Fire resistance
   performance

0

0

Fire test according to EN 1363-1,
15 min.- 90 min.
(15 min. / 30 min. / 60 min. / 90 min.)

NFPA 251 standard fire resistance test,   10 minute level

Flammable vapor
   ventilation

0

0

Flammable vapor ventilation is   recommended.
Check sound pressure formation inside the cabinet during ventilation.

Ventilation is not recommended.
(Recommended to use level of container recommended in NFPA 30.)

Flammable vapor ventilation

Keeps flammable vapors below the LEL   concentration and removes odors through ventilation.

Flammable vapor ventilation

It seals the ventilation holes, and an   odor occurs inside the storage cabinet.

The risk of ignition is increased as the concentration of flammable vapor   increases.

Safety Cover

0

0

Automatic door and ventilation closure   during fire test

In the case of a fire test, test with the   ventilation hole blocked.
Fire safety not considered when connecting to external ventilation   facilities.

Comparison of EN 14470-1 and NFPA 30International Standards

Fire resistance performance 60-minutestype

Type

Model

Under

SC2-60F-0812D2

SC2-60F-0809D1

SC2-60F-0806D1-CL

SC2-60F-0806D1-CR

SC2-60F-0706D1-C

※ LC Connected service scheduled for release

Accessories (Type 60)

Accessory

Description

(W x D x H, mm)

SC2-60F-0806D1-CL/SC2-60F-0806D1-CR

SC2-60F-0706D1-C

Plinth (Side)

480 x 340 x 350

AAAF15364

AAAF15364

Extraction Module EM-33) (230V, 60Hz)

348 x 498 x 343

AAAF1536

AAAF1536


※ Please refer to page 199 for details on EM-33 compatible filter.

※ Please refer to page 208 for detailed images of shelf, sump,drawer, and tray.

Dimension (Unit: mm)

Model

A

B

C1)

D(Diameter)

Under (Door)

SC2-60F-0806D1-CR/CL

125

530

1070

102

SC2-60F-0706D1-C

125

480

1070

102


1) C is the maximum depth when the door isopened.

60F_Acc_Dimension.jpg

Bottom Collecting Pump Specification by Model

Model

A

SC2-60F-0806D1-CL/CR

503 x 418 x 35

SC2-60F-0706D1-C

503 x 418 x 35


※ Choose one between a epoxy powder coated steel and a stainlesssteel material

Shelf

Bottom Collecting Sump

Tray (PP)

Shelf

Bottom Collecting Sump

Tray (PP)

Drawer

Fume Extraction Module (EM-33)

SC_All_Acc_img06.jpg

Drawer

Fume Extraction Module (EM-33)

Plinth (Side) + EM-33


产品分类